Introduction
vSAN Express Storage Architecture (ESA) is the recommended storage architecture for all new VMware Cloud Foundation 9 deployments. ESA represents a ground-up redesign of the vSAN storage stack, purpose-built to exploit the performance characteristics of modern NVMe flash media. In this post, we explore the vSAN ESA architecture, design decisions, VCF 9.1’s new Auto-RAID capability, and best practices for storage policy design.
Architectural Overview
The diagram below illustrates the vSAN ESA architecture in a VCF 9 environment, from the NVMe hardware layer through the vSAN data path and management plane:
ESA vs OSA: Architecture Comparison
vSAN ESA fundamentally differs from the original vSAN Original Storage Architecture (OSA):
| Feature | OSA | ESA |
|---|---|---|
| Drive Tiers | Cache + Capacity (2-tier) | Single NVMe pool (1-tier) |
| NVMe Support | Limited (cache tier only) | Full NVMe-native throughout |
| Compression | Software only (post-process) | Always-on cluster service (VCF 9.1), hardware-assisted |
| Snapshot Performance | Degrades under load | Metadata-based, near-zero impact |
| RAID-5/6 Efficiency | Requires 6 hosts (RAID-6) | Available with 4 hosts (RAID-5), auto-selected via Auto-RAID in VCF 9.1 |
| Drive Health Monitoring | Basic health alerts | Proactive Hardware Management (PHM) for predictive NVMe failure detection |
| File System | VMFS-based (COW) | Log-Structured File System (LFS) |
| Minimum Hosts | 3 | 3 |
| Minimum Drives/Host | 1 cache + 1 capacity | 3 NVMe (all-flash single tier) |
ESA Key Design Decisions
Single-Tier NVMe Pool
ESA eliminates the two-tier cache/capacity split used in OSA. All NVMe drives contribute to a single unified storage pool, delivering:
- Consistent low-latency I/O across all stored objects regardless of working set size
- Simplified capacity planning with no cache-to-capacity ratio calculations required
- Minimum 3 NVMe drives per host for ESA (the Broadcom Compatibility Guide lists ESA-certified NVMe drives)
- All drives must be certified for ESA: not all NVMe drives qualify; refer to the Broadcom Compatibility Guide (BCG) for the ESA Compatibility category
Log-Structured File System (LFS)
ESA uses a purpose-built Log-Structured File System optimized for NVMe characteristics:
- Sequential write patterns to all NVMe devices, maximizing write throughput
- In VCF 9.1, compression is now an always-on cluster service rather than a per-policy toggle, reducing write amplification and extending drive life with no configuration required
- Efficient space reclamation through background compaction without impacting foreground I/O
Near-Zero Impact Snapshots
ESA’s log-structured architecture enables a metadata-based snapshot engine that is fundamentally different from OSA’s copy-on-write approach:
- Snapshots are tracked through metadata pointers rather than copying data blocks, so creation is crash-consistent without stunning the VM
- Snapshot deletion is largely a metadata operation, acknowledged immediately, with underlying data reclaimed asynchronously, and is dramatically faster than OSA’s redo-log-based mechanism
- Snapshot trees do not degrade read/write performance, enabling efficient use of snapshots for backup integration (VMware Live Recovery)
- Supports VMware Live Recovery with RPO as low as 1 minute for vSAN-to-vSAN replication in supported configurations
New in VCF 9.1: Auto-RAID
VCF 9.1 introduces Auto-RAID, a fully system-managed approach to data resilience that replaces manual RAID/FTT policy selection as the recommended default for vSAN ESA clusters:
- A single “vSAN ESA Auto RAID Policy” governs all vSAN 9.1 clusters cluster-wide: no explicit resilience settings are stored in the policy itself; vSAN senses cluster characteristics (host count, topology) and applies the optimal RAID level automatically
- Standard clusters with 6+ hosts: FTT=2 using RAID-6 (1.5x capacity overhead)
- Standard clusters with 3–5 hosts: FTT=1 using RAID-5, always using the 2+1 erasure code (1.5x capacity overhead)
- Fewer than 3 hosts: FTT=0 (1.0x capacity overhead) until the cluster scales up
- Stretched clusters and 2-node clusters have their own Auto-RAID resilience tables, layering a mirror-based site/host disaster tolerance on top of the same erasure-coding logic
- Cluster changes (adding/removing hosts) are re-evaluated dynamically, so resilience adjusts automatically as the cluster grows
- All new VCF 9.1 clusters use Auto-RAID by default. Existing clusters upgraded to 9.1 keep their prior storage policy or Auto-Policy Management configuration until migrated, though vSAN surfaces a health alert recommending the switch
This is a meaningful shift from earlier vSAN ESA guidance (including VCF 9.0), where administrators manually selected RAID-1/5/6 per policy based on host count and workload criticality.
Proactive Hardware Management (PHM) for NVMe Drives
vSAN’s Proactive Hardware Management (PHM) capability applies to ESA NVMe drives in VCF 9:
- Predictive detection: PHM surfaces disk predictive-failure events generated by the OEM vendor through a registered Hardware Support Manager (HSM), rather than waiting for a hard failure
- Continuous polling: PHM checks for HSM-generated hardware failure events every 10 minutes
- Administrator-driven remediation: Based on the predictive failure signal, PHM lets you take the appropriate remediation action (such as proactively evacuating data from the affected drive) before an unplanned failure occurs
- Alert integration: PHM events surface through the vSAN management service on vCenter and integrate with vSAN Health and Skyline Health for fleet-wide visibility in VCF Operations
Requires a supported Hardware Support Manager registered to vCenter: without an HSM, vSAN cannot receive OEM predictive-failure signals for PHM.
vSAN ESA Storage Policies in VCF 9
Storage policies in vSAN ESA are defined through VM Storage Policies applied at the VM or VMDK level. As of VCF 9.1, Auto-RAID is the recommended default for resilience settings (see above); the guidance below reflects the underlying RAID mechanics and remains relevant for pre-9.1 clusters or environments not yet migrated to Auto-RAID.
Key Policy Parameters
Failures to Tolerate (FTT): the number of host failures the cluster can sustain:
- FTT=1 with RAID-1 (mirroring): minimum 3 hosts required
- FTT=1 with RAID-5 (erasure coding): minimum 4 hosts, more space-efficient than RAID-1
- FTT=2 with RAID-6 (erasure coding): minimum 6 hosts, recommended for production workloads
Storage Policy Best Practices for VCF 9:
- On VCF 9.1, start with the vSAN ESA Auto RAID Policy as the datastore default: it removes the guesswork of matching RAID level to host count and adjusts automatically as the cluster scales
- If manual policies are still required (pre-9.1 clusters, or specific IOPS limit / Object Space Reservation / stretched-cluster site-locality needs), use RAID-5/FTT=1 for general workloads with 4+ hosts and RAID-6/FTT=2 for business-critical VMs requiring tolerance of 2 simultaneous host failures
- Define separate storage policies for management VMs and workload VMs only where Auto-RAID’s cluster-wide policy doesn’t fit the requirement (for example, custom IOPS limits)
- Enable storage-based policy management (SPBM) integration with VCF Automation for self-service policy assignment
vSAN File Services
VCF 9 supports vSAN File Services on ESA clusters:
- Supports up to 500 file shares per cluster, of which up to 100 can be SMB
- Provides NFS v3/v4.1 and SMB protocol support for workloads requiring shared file storage
- VCF 9.1 delivers up to 2x faster metadata operations for SMB workloads
- File services VMs are deployed automatically within the vSAN cluster
- Useful for Kubernetes persistent volumes (NFS-backed) and legacy application shared storage requirements
vSAN ESA and VMware Live Recovery Integration
VCF 9’s vSAN ESA integrates with VMware Live Recovery for disaster recovery:
- Host-based vSAN-to-vSAN replication with RPO as low as 1 minute for protected VMs
- Metadata-based snapshots enable efficient replication without degrading production I/O
- VCF 9.1 adds seeding for vSAN replication, using existing replicas to avoid full re-synchronization when creating new replication pairs
- Failover orchestration is managed through VCF Operations or the dedicated Live Recovery management interface
- Supports both on-premises-to-on-premises and on-premises-to-VMware Cloud replication topologies
Operational Best Practices
Host maintenance and replacement:
- Before removing a host from the cluster, use vSphere maintenance mode with “Ensure Accessibility” or “Full Data Migration” to safely migrate vSAN objects
- For ESA, a minimum of 3 fully operational hosts (not including the host in maintenance) is required to maintain FTT=1 protection
Capacity management:
- Monitor vSAN capacity from VCF Operations > Cost and Capacity Management
- VCF 9.1’s Auto-RAID standardizes capacity overhead per cluster type (1.5x for standard clusters, 3x for stretched, 2x for 2-node), which simplifies capacity forecasting compared to mixed manual policies
- Plan for vSAN resync capacity: maintain 10-15% slack capacity for background resync after a host failure or replacement
Monitoring and health:
- Enable Skyline Health integration in VCF Operations for proactive hardware health alerts
- Review PHM alerts regularly: a predictive-failure signal indicates a drive is near end of life and should be scheduled for replacement
- vSAN performance diagnostics are available from vCenter > Monitor > vSAN > Performance
What’s Next
In the next post, we cover VCF 9 Lifecycle Management with VCF Operations: Unified Upgrades and Fleet Management, walking through the unified upgrade workflow for ESX, vCenter, NSX, and vSAN, the new simplified licensing model, and fleet-level health monitoring across every VCF domain.
Further Reading (Official Broadcom Documentation)
- vSAN 9.1 New Features: Release Notes
- Selecting the Best RAID Configuration for a vSAN Storage Cluster
- Managing Proactive Hardware
- vSAN File Service